Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Standard value table for chassis related parts

UEN00227-00 20 Standard value table 16 PC210, 230, 240-8 Applicable model PC240LC, 240NLC-8 Cate- gory Item Measurement condition Unit Standard value for new machine Judgement criteria Work equipment Time lag Boom • Hydraulic oil temperature: Within operating range • Engine running at low idle • Working mode: P mode • Time required from raise stroke end till bucket touches ground and pushes up machine front • For measuring posture, see Work equipment 5 sec. Max. 1.0 Max. 1.2 Arm • Hydraulic oil temperature: Within operating range • Engine running at low idle • Working mode:

P mode • Time required from dumping stroke end till bucket stops momentarily after control lever is tilted to digging and starts to move again • For measuring posture, see Work equipment 6 sec. Max. 2.0 Max. 2.8 Bucket • Hydraulic oil temperature: Within operating range • Engine running at low idle • Working mode: P mode • Time required from dumping stroke end till bucket stops momentarily after control lever is tilted to digging and starts to move again • For measuring posture, see Work equipment 7 sec. Max. 1.0 Max. 3.6 Internal leackage Cylinders • Hydraulic oil temperature:

Within operating range • Engine running at high idle • Leakage amount for one minute with cylinder or travel to be measured in relief condition cc/min 4.5 20 Center swivel joint cc/min 10 50 Performance in compound operation Swerving amount in simultaneous operation of work equipment and travel • Hydraulic oil temperature: Within operating range • Engine at high idle • Working mode: P mode • Traveling speed:

Lo • On hard and flat ground, make approach run of 10 m and then mea- sure deviation in the travel of 20 m • For measuring posture, see Travel 2 and 3 mm Max.200 Max.220 Characteristics of PC flow control valve Time required for turning from 0 to 90° with boom raised • Hydraulic oil temperature: Within operating range • Engine at high idle • Working mode: P mode • Rated load applied to bucket (0.8m3: 1,440kg) • On hard and flat ground, set arm vertically and lower back of bucket to ground • Time required till passing spot of 90° starting from illustrated posture and with boom raised • For measuring posture, see Work equipment 8 sec.

4.3 ± 0.4 (Reference value) — Discharge amount of hydraulic pump See performance of hydraulic pump (next page)