Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Measuring blow-by pressure

30 Testing and adjusting UEN00228-00 Measuring blow-by pressure 1 a Measuring tools for blow-by pressure k Stop the machine on a level ground and lower the work equipment to the ground. a Measure the blow-by pressure under the fol- lowing condition. q Engine coolant temperature: Within oper- ating range q Hydraulic oil temperature: Within operat- ing range 5. After finishing measurement, remove the mea- suring tools and return the removed parts. 1. Remove the undercover of the hydraulic pump. 2. Install tool and adapter [1] of blow-by checker D1 or blow-by tool D2 to breather hose (1) and connect gauge [2]. 3.

Start the engine, set the working mode in the power mode (P), and turn the swing lock switch ON. a If the swing lock switch is turned ON, the main relief valve is set for high-pressure relief. 4. While running the engine at high idle, relieve the arm circuit and measure the blow-by pres- sure. a Read the gauge when the pointer is stabi- lized. PC210, 230, 240-8 13 Symbol Part No. Part name D 1 799-201-1504 Blow-by checker 2 799-790-3300 Blow-by tool