30 Testing and adjusting UEN00228-00 k If the engine cannot be started, you may measure the fuel return rate while rotating the engine with the starting motor. Do not rotate for more than 20 seconds continu- ously, however, for protection of the starting motor. 5) After finishing measurement, remove the measuring tools and return the removed parts. 3 Joint bolt: 24 ± 4 Nm {2.4 ± 0.4 kgm} 3. Measuring return rate from injector 1) Open the engine hood and disconnect return hose (3) of the cylinder head. 5) After finishing measurement, remove the measuring tools and return the removed parts. 3 Joint bolt:
24 ± 4 Nm {2.4 ± 0.4 kgm} 2) Connect testing tool G3 to the cylinder head side and insert its end in measuring cylinder G4 . 3) Connect blocking tool G3 to the return hose side to prevent the fuel from leaking. 4) Run the engine at low idle and measure the return rate from the injector. a If the return rate from the injector is in the following range, it is normal. At low idle Max. 180 cc/min During cranking Max. 90 cc/min PC210, 230, 240-8 19