Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Measuring and adjusting oil pressure in work equipment, swing, and travel circuits

30 Testing and adjusting UEN00228-00 Measuring and adjusting oil pressure in work equipment, swing, and travel circuits 1 PC240-8 a Measuring and adjusting tools for oil pressure in work equipment, swing, and travel circuits k Stop the machine on a level ground and lower the work equipment to the ground. Then, release the residual pressure from the hydraulic circuit. For details, see "Releasing residual pressure from hydraulic circuit". 2) Install nipples J2 and connect oil pressure gauges [1] of hydraulic tester J1 . a Use the oil pressure gauges of 58.8 MPa {600 kg/cm 2 }.

Measuring a The oil pressure in the work equipment, swing, and travel circuits (pump discharge pressure) can be checked with monitoring function of the machine monitor, too (For details, see “Special functions of machine monitor”). q Monitoring code: 01101 R pump pressure a Measure the oil pressure in the work equip- ment, swing, and travel circuits under the fol- lowing condition. q Monitoring code: 01100 F pump pressure q Hydraulic oil temperature: Within operat- ing range PC240-8 1. Preparation work 1) Open the side cover of the pump room and remove oil pressure pickup plugs (1) and (2). q (1): Front pump discharge pressure pickup plug q (2): Rear pump discharge pressure pickup plug 2.

Combination of pump, actuator, and valve a When the oil from the pumps is divided, the front pump and rear pump act inde- pendently on each actuator. Note that dif- ferent actuators relieve different valves. a When the work equipment circuit or swing circuit is relieved singly, the oils of the pumps are merged. When the travel circuit is relieved singly, the oils of the pumps are divided. PC210, 230, 240-8 27 Symbol Part No. Part name J 1 799-101-5002 790-261-1204 Hydraulic tester Digital hydraulic tester 2 799-101-5220 Nipple (10 × 1.25 mm) 07002-11023 O-ring P J2 C210/230-8 J 2 PC2 10/230-8 2 1 Warning:Test points reversed on PC210/230-8 pump