Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Measuring and adjusting oil pressure in pump LS control circuit

UEN00228-00 30 Testing and adjusting Adjusting Adjusting LS valve a If the LS differential pressure is abnormal, adjust the LS valve according to the following procedure. q (8): Front pump LS valve q (9): Rear pump LS valve 3) Start the engine. 4) Run the engine at high idle, operate the travel speed switch and travel lever, and measure the output pressure in each case. a Measuring condition and method of judgment: If the output pressures are in the following ratio, the LS-EPC valve is normal. PC240-8 Note:Move the travel lever to a degree that the PPC oil pressure switch is turned ON (before the track starts moving).

5) After finishing measurement, remove the measuring tools and return the removed parts. 1. While fixing adjustment screw (10), loosen locknut (11). 2. Turn adjustment screw (10) to adjust the differ- ential pressure. a If the adjustment screw is q Turned to the right, the differential pressure is increased. q Turned to the left, the differential pressure is decreased. a Quantity of adjustment (LS differential pressure) per turn of adjustment screw: Approx. 1.1 MPa {Approx. 10.8 kg/cm 2 } 3. While fixing adjustment screw (10), tighten locknut (11). 40 PC210, 230, 240-8 PC2 10/230-8 8 9 Travel speed Operation of lever Output pressure Lo Travel lever in neutral Approx. 2.9 MPa {Approx.

30 kg/cm2} Hi Travel lever operated a little (Note) 0 MPa {0 kg/cm2}