UEN00228-00 30 Testing and adjusting a Measuring tools for PPC valve output pressure k Stop the machine on a level ground and lower the work equipment to the ground. Then, release the residual pressure from the hydraulic circuit. For details, see “Releasing residual pressure from hydrau- lic circuit”. a Before measuring the PPC valve output pres- sure, check that the basic pressure of the con- trol circuit is normal. a Measure the solenoid valve output pressure under the following condition. a If the output pressure is as follows, the PPC valve is normal. q Hydraulic oil temperature: Within operating range 1. Disconnect the hose of the PPC circuit to be measured.
a For the hose to be disconnected, see “Connecting points of PPC piping”. 6. After finishing measurement, remove the mea- suring tools and return the removed parts. 2. Install adapter P2 and connect the discon- nected hose again. 3. Install nipple [1] of hydraulic tester P1 and con- nect it to oil pressure gauge [2]. a Use the oil pressure gauge of 5.9 MPa {60 kg/cm 2 }. a The figure shows the measuring tools con- nected to the hose of the bucket dump PPC circuit. 4. Start the engine and set the working mode in the power mode (P). 5. Run the engine at high idle and measure the oil pressure with the control lever in neutral and moved to the stroke end. 46 PC210, 230, 240-8 Symbol Part No.
Part name P 1 799-101-5002 Hydraulic tester 790-261-1204 Digital hydraulic tester 2 799-401-3100 Adapter (Size 02) 3 799-401-3200 Adapter (Size 03) Operation of lever Output pressure Neutral 0 MPa {0 kg/cm2} Stroke end Almost same as control cir- cuit basic pressure (See standard values table)