UEN00229-00 30 Testing and adjusting 4. Executing monitoring After the “Executing monitoring screen” is dis- played, perform the necessary operation of the machine and check the monitoring information. a Monitoring information is indicated by value, ON/OFF, or special display. a The unit of display can be set to SI unit, metric unit, or inch unit with the Initializa- tion function in the service mode. 6. Changing machine setting mode To change the setting of the working mode, travel speed, or auto-deceleration during moni- toring, operate the corresponding switch under the current condition, and the mode setting screen is displayed.
While this screen is displayed, if the corre- sponding switch is operated further, the corre- sponding mode is changed. a After finishing changing the setting, press [F6] to return to the monitoring information screen. a If the setting is changed during monitoring, the new setting is held even after the screen returns to the ordinary screen after monitoring is finished. 5. Holding monitoring information The monitoring information can be held and reset with the function switches. q [F3]: Reset holding q [F4]: Hold information (displayed data) q [F5]:
Return to monitoring selection menu screen a If the working mode is changed to breaker mode [B], the screen to confirm the change of the setting is displayed as in changing the working mode on the ordi- nary screen. 22 PC210, 230, 240-8