UEN00229-00 30 Testing and adjusting 4. Resetting abnormality record 1) While the “Electrical systems” screen is displayed, perform the following operation with the numeral input switches. 3) After the “Electrical sys. error reset” screen is displayed, operate the function switches. q [F5]: Return to “Electrical systems” screen (Reset mode) q Operation of switches (While pressing [4], perform the operation in order): [4] + [1] o [2] o [3] q [F6]: Execute reset a The following figure shows the screen displayed when the items are reset one by one (which is a little different from the screen displayed when all the items are reset together).
2) Check that the screen is set in the reset mode, and then reset the items one by one or together with the function switches. a If the screen is set in the reset mode, [CLEAR] graphic mark is indicated at [F2]. 4) If the screen to notify completion of reset is displayed and then the “Electrical sys- tems” (reset mode) screen is displayed, the reset of the abnormality record is com- pleted. a After a while, the screen returns to the “Electrical systems” screen. q [F2]: Reset all items q [F3]: Move to lower item q [F4]: Move to upper item q [F5]: Return to abnormality record screen q [F6]: Reset selected item a To reset items one by one:
Select the item to be reset with [F3] or [F4] and press [F6]. a To reset all items together: Press [F2], and all the items are reset, regardless of selection of the items. a If [ E ] is displayed on the left of a fail- ure code, the resetting operation is accepted but the information is not reset. 28 PC210, 230, 240-8