Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Special functions of machine monitor

UEN00229-00 30 Testing and adjusting Default (Setting of Breaker Detect) Check or change various settings related to the machine monitor and machine by "Default". The function of setting breaker automatic judgment is used to set the display to give warning when the breaker is used in an improper working mode. 3. Selecting display setting After the "Breaker Detect" screen is displayed, select the setting with the function switches. q [F3]: Move to lower item q [F4]: Move to upper item q [F5]: Cancel selection and return to Default screen 1. Selecting menu Select "Default" on the service menu screen. q [F6]:

Confirm selection and return to Default screen a When the machine is delivered, Disable is set. 2. Selecting sub menu After the "Default" screen is displayed, select "Breaker Detect" with the function switches or numeral input switches. a Select this item similarly to an item on the Service menu screen. a Display of "Breaker Detect" 44 PC210, 230, 240-8