30 Testing and adjusting UEN00229-00 Adjustment (Setting of Pump absorption torque (F)) The operator can adjust various items related to the machine with the machine monitor. The pump absorption torque (F) function is used to finely adjust the absorption torque on the front side of the hydraulic pump. 3. Selecting absorption torque After the "Pump Absorption Torque (F)" screen is displayed, select a set value on the right side with the function switches. q Set value: For actual torque adjustment value, see table q [F3]: Increase set value 1. Selecting menu Select "Adjustment" on the service menu screen. q [F4]: Decrease set value q [F6]:
Confirm setting and return to Adjust- ment menu screen a The 3 digits on the left side do not vary since they are the code of this function. 2. Selecting sub menu After the Adjustment screen is displayed, select "Pump Absorption Torque (F)" with the function switches or numeral input switches. a Select this item similarly to an item on the Service menu screen. a Relationship between set value and torque adjustment value 008 –39.2 Nm {–4 kgm} PC210, 230, 240-8 45 Set Code valu Torque adjustment value e +39.2 Nm {+4 kgm} +29.4 Nm {+3 kgm} +19.6 Nm {+2 kgm} +9.8 Nm {+1 kgm} 0 Nm {0 kgm} –9.8 Nm {–1 kgm} –19.6 Nm {–2 kgm} –29.4 Nm {–3 kgm}