UEN00229-00 30 Testing and adjusting Display of fuel consumption This function calculates the hourly fuel consump- tion from the actual fuel consumption in a measur- ing period and indicates it. 1. Selecting menu Select "Fuel consumption" on the service menu screen. 3. Display and function during measurement Clock mark (a) flashes during measurement. a While the fuel consumption is being mea- sured, the operator can work with the operator mode and other functions.
Mea- surement is not finished until this screen is displayed again and [F1] is pressed (Even if the starting switch is turned OFF, this function is kept effective, although fuel consumption is measured only while the engine is running). 2. Starting measurement After the screen of Fuel consumption is dis- played, start measurement with the function switches. q [F1]: Start q [F2]: Clear 4. Finishing measurement Press [F1], and measurement is finished and the data are displayed on the finishing date and time side. q [F5]: Return to Service menu screen a When the screen of Fuel consumption is displayed, if a data is indicated, it is the data of the previous measurement.
This data is not an obstacle to new measure- ment and can be reset by pressing [F2]. a If [F1] is pressed, the data is displayed on the starting date and time side and mea- surement starts. 5. Displaying fuel consumption If the measurement is finished, the hourly fuel consumption calculated from the fuel con- sumption calculated by the engine controller and the elapsed time are displayed. a The display unit of the fuel changes according to the unit set with the default (unit setting) function. SI and meter: l /h inch: gal/h 52 PC210, 230, 240-8