Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Procedure for testing diodes

30 Testing and adjusting UEN00230-00 Procedure for testing diodes 1 a Test the assembled-type diode (8-pin) and the single diode (2-pin) according to the following procedure. a The conductive directions of the assembled- type diode are as follows. 2. When using analog circuit tester 1) Set the tester in the resistance range. 2) Apply the leads of the tester as explained below and check the movement of the pointer. i) Apply the red (+) lead of the tester to the anode (P) side of the diode and apply the black (–) lead to the cath- ode (N) side. ii) Apply the red (+) lead of the tester to the cathode (N) side of the diode and apply the black (–) lead to the anode (P) side.

3) Judge the condition of the diode by the movement of the pointer. a The conductive direction of the single diode is indicated on the surface of the diode. q The pointer does not move in i) but moves in ii): The diode is normal (The moving range (resistance) depends on the type and selected range of the tester, however). q The pointer moves in both i) and ii): The diode is defective (Internal short circuit). 1. When using digital circuit tester 1) Set the tester in the diode range and check the indicated value. a When an ordinary circuit tester is used, the voltage of the internal bat- tery is indicated.

2) Apply the red (+) lead of the tester to the anode (P) side of the diode and apply the black (–) lead to the cathode (N) side and check the indicated value. 3) Judge the condition of the diode by the indicated value. q The pointer moves in neither of i) and ii): The diode is defective (Internal disconnection). q The indicated value does not change: The diode does not have conductivity (Defective). The indicated value changes: The diode has conductivity (Normal). Note: In the case of a silicon diode, a value in the range from 460 to 600 is indi- cated. PC210, 230, 240-8 7