Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA227] Sens Supply 2 Volt High Error

UEN00240-00 40 Troubleshooting Failure code [CA227] Sens Supply 2 Volt High Error 1 Circuit diagram related to sensor power supply 2 46 PC210, 230, 240-8 User cod e Failure code Trouble Sensor power supply 2 voltage high error (Engine controller system) E15 CA227 Contents trouble of • High voltage was detected in sensor power supply 2 circuit. Action o controlle • Fixes boost pressure value and continues operation. f • Fixes charge temperature value and continues operation. r • Limits output and continues operation. Problem t appears o machine hat n • Engine output lowers. Related inf mation or- • Method of reproducing failure code: Turn starting switch ON.

Possible cau and stand value in nor state Cause ses Defective wiring harness ard 1 connector mal 2 Defective engine controller Standard value in normal state/Remarks on troubleshooting Connecting parts between each sensor – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation If cause 1 is not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)