Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA272] IMV/PCV1 Open Error

UEN00240-00 40 Troubleshooting Failure code [CA272] IMV/PCV1 Open Error 1 Circuit diagram related to supply pump actuator (metering unit) 50 PC210, 230, 240-8 User code Failure code Trouble IMV/PCV1 open error (Engine controller system) E10 CA272 Contents of • trouble Opening was detected in drive circuit of supply pump actuator. Action of • controller None in particular. Problem that • appears on • machine Engine runs but its operation is unstable. Common rail fuel pressure rises above command value. Related infor- • mation Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective supply pump actu- 1 ator a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CP3 PUMP REGULATOR (male) Resistance Between (1) – (2) Max. 5 z Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) CP3 PUMP REGULATOR (female) (1) – Resis- M tance ax.

10 z Wiring harness between CE01 (female) (32 – CP3 PUMP REGULATOR (female) (2) ) Resis- M tance ax. 10 z Hot short (Short circuit with 3 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CE01 (female) (2) CP3 PUMP REGULATOR (female) (1) – Voltage M ax. 3 V Short circuit in wiring harness 4 (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) each of CE01 (female) pins (With all wiring harness connectors disconnected) – Resis- tance Min.

100 kz Defective wiring harness 5 connector Connecting parts between supply pump actuator – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 6 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE01 (female) Resistance Between (2) – (32) Max. 5 z