Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA271] IMV/PCV1 Short Error

40 Troubleshooting UEN00240-00 Failure code [CA271] IMV/PCV1 Short Error 1 Circuit diagram related to supply pump actuator (metering unit) PC210, 230, 240-8 49 User code Failure code Trouble IMV/PCV1 short circuit error (Engine controller system) E10 CA271 Contents of • trouble Short circuit was detected in drive circuit of supply pump actuator. Action of • controller None in particular. Problem that • appears on • machine • Engine speed does not rise from low idle. Engine output lowers. Common rail fuel pressure rises above command value. Related infor- • mation Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective supply pump actu- 1 ator a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CP3 PUMP REGULATOR (male) Resistance Between (1) – chassis ground Min. 100 kz Ground fault in wiring har- 2 ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) CP3 PUMP REGULATOR (female) (1) – Resis- tance Min.

100 kz Short circuit in wiring har- 3 ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE01 (female) (2) each of CE01 (female) pins (With all wiring harness connectors disconnected) – Resis- tance Min. 100 kz Defective wiring harness 4 connector Connecting parts between supply pump actuator – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CE01 (female) Resistance Between (2) – chassis ground Min. 100 kz