Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA238] Ne Speed Sens Supply Volt Error

UEN00240-00 40 Troubleshooting Failure code [CA238] Ne Speed Sens Supply Volt Error 1 Circuit diagram related to engine Ne speed sensor 48 PC210, 230, 240-8 User code Failure code Trouble Ne speed sensor power supply voltage error (Engine controller system) E15 CA238 Contents of • trouble Low voltage was detected in power supply circuit of engine Ne speed sensor. Action of • controller Continues control with signal from engine Bkup speed sensor. Problem that • appears on • machine Engine does not start easily. Engine hunts. Related infor- • mation Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective sensor or wiring 1 harness a Disconnect connector with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Disconnect sensor and wiring harness at right in order and carry out operation to reproduce trouble. If "E" of failure code goes off when sensor or wiring harness is disconnected, that sensor or wiring har- ness is defective. Ne speed sensor C RANK SENSOR Engine wiring har- C ness E01 Defective wiring harness 2 connector Connecting parts between each sensor – engine wiring harness – engine controller may be defective.

Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation