40 Troubleshooting UEN00241-00 Failure code [CA441] Battery Voltage Low Error 1 PC210, 230, 240-8 15 User code Failure code Trouble Battery voltage low error (Engine controller system) E10 CA441 Contents of trouble • There is low voltage in controller power supply circuit. Action of controller • None in particular. Problem that appears on machine • Engine stops. • Engine does not start easily. Related infor- mation • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Looseness or corrosion of battery terminal Battery terminal may be loosened or corroded.
Check it directly. 2 Low battery voltage a Prepare with starting switch OFF, then keep starting switch OFF and start engine and carry out troubleshooting in each case. Battery (1 piece) Starting switch Voltage Between (+) – (–) terminals OFF Min. 12 V START Min. 6.2 V 3 Defective fuse No. 19 If fuse is broken, circuit probably has ground fault. (See Cause 6) 4 Defective relay for engine controller power supply a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Replace relay (R23, R24) for engine controller with another relay and perform reproducing operation. If "E" of failure code goes off at this time, replaced relay is defective.
5 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-19 – R23, R24 (female) (3) Resis- tance Max. 10 z Wiring harness between R23, R24 (female) (5) – CE03 (female) (3) Resis- tance Max. 10 z Wiring harness between CE03 (female) (1) – chassis ground (T12) Resis- tance Max. 10 z 6 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-19 – R23, R24 (female) (3) Resis- tance Min.
100 kz Wiring harness between R23, R24 (female) (5) – CE03 (female) (3) Resis- tance Max. 10 z 7 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE03 (female) (3) – CE03 (female) (1) pin (with battery terminal disconnected) Resis- tance Min. 100 kz Wiring harness between CE03 (female) (3) – each of CE02 (female) pins (With battery ter- minal disconnected) Resis- tance Min. 100 kz Wiring harness between CE03 (female) (1) – each of CE02 (female) pins (With battery ter- minal disconnected) Resis- tance Min. 100 kz