Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA553] Rail Press High Error

UEN00241-00 40 Troubleshooting Failure code [CA488] Chg Air Temp High Torque Derate 1 Failure code [CA553] Rail Press High Error 1 26 PC210, 230, 240-8 User code Failure code Trouble Charge air temperature high torque derate (Engine controller system) E15 CA488 Contents of trouble • Temperature signal of boost pressure/temperature sensor exceeded control upper temperature limit. Action of controller • Limits output and continues operation. Problem that appears on machine • Engine output lowers. Related infor- mation • Boost temperature can be checked with monitoring function. (Code: 18500 Boost temperature) • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Lowering of cooling perfor- mance of aftercooler Cooling performance of aftercooler may be low. Check following points directly. • Looseness and breakage of fan belt. • Insufficiency of cooling air • Clogging of aftercooler fins 2 Abnormal rise of turbo- charger outlet temperature Outlet temperature of turbocharger may be abnormally high. Check related parts directly. 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.) User code Failure code Trouble Common rail pressure high error (Engine controller system) E11 CA553 Contents of trouble • There is high pressure error in common rail circuit. Action of machine monitor • None in particular. Problem that appears on machine • Engine sound becomes large when no or light load is applied. • Engine output lowers. Related infor- mation • Common rail pressure can be checked with monitoring function. (Code: 36400 Common rail pressure) • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defect in related system If another failure code is displayed, carry out troubleshooting for it. 2 Defective connection of ground terminal Ground terminal may be connected defectively. Check following ter- minals directly. • Ground terminal of machine ((–) terminal of battery) • Ground terminal of engine • Ground terminal of engine controller • Ground terminal of starting motor 3 Breakage of O-ring of supply pump actuator O-ring of supply pump actuator may be broken. Check it directly.