Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [CA2186] Throt Sens Sup Volt Low Error

40 Troubleshooting UEN00241-00 Failure code [CA2186] Throt Sens Sup Volt Low Error 1 Circuit diagram related to fuel control dial PC210, 230, 240-8 39 User code Failure code Trouble Throttle sensor supply voltage low error (Engine controller system) E14 CA2186 Contents of trouble • Low voltage was detected in throttle sensor power supply circuit. Action of controller • If trouble occurs while starting switch is in ON position, controller fixes voltage value to level just before detection of trouble and continues operation. • If starting switch is turned ON while voltage is abnormally high, controller continues operation with voltage at 100% value.

Problem that appears on machine • Engine speed cannot be controlled with fuel control dial. Related infor- mation • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Ground fault in wiring har- 1 ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE02 (female) (22) – P20 (female) (1) Resis- M tance in.

100 kz Short circuit in wiring har- 2 ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CE02 (female) (9) – each of CE02 (female) pins (With P20 dis- connected) Resis- M tance in. 100 kz Defective wiring harness 3 connector Connecting parts between fuel control dial – machine wiring har- ness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 4 Defective engine controller If causes 1 – 3 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)