Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DA25KP] 5V Sensor 1 Power Abnormality

UEN00241-00 40 Troubleshooting 52 PC210, 230, 240-8 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 2 Ground fault in wiring har- ness (Short circuit with GND circuit) Wiring harness between C01 (female) (9) – J06 – P07 (female) (3) [Swing RIGHT PPC pressure sensor system] Resis- tance Min. 1 Mz Wiring harness between C01 (female) (9) – J06 – P25 (female) (3) [F pump pressure sensor system] Resis- tance Min. 1 Mz Wiring harness between C01 (female) (9) – J06 – P26 (female) (3) [R pump pressure sensor system] Resis- tance Min.

1 Mz 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (9) – J06 – P01 (female) (3) [Bucket CURL PPC pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – J06 – P03 (female) (3) [Swing LEFT PPC pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – J06 – P04 (female) (3) [Arm IN PPC pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – P05 (female) (3) [Bucket DUMP PPC pressure sensor sys- tem] Voltage Max.

1 V Wiring harness between C01 (female) (9) – J06 – P06 (female) (3) [Boom RAISE PPC pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – J06 – P07 (female) (3) [Swing RIGHT PPC pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – J06 – P25 (female) (3) [F pump pressure sensor system] Voltage Max. 1 V Wiring harness between C01 (female) (9) – J06 – P26 (female) (3) [R pump pressure sensor system] Voltage Max. 1 V 4 Defective pump controller If causes 1 – 3 are not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)