Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DWA2KA] Service Sol Discon

UEN00242-00 40 Troubleshooting Failure code [DWA2KA] Service Sol Discon 1 Circuit diagram related to service solenoid 42 PC210, 230, 240-8 User code Failure code Trouble Service solenoid disconnection (Pump controller system) — DWA2KA Contents of trouble • When output to service solenoid is turned OFF, disconnection was detected in circuit. Action of controller • None in particular. (Since no current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem that appears on machine • Hydraulic circuit for attachment does not change to single operation circuit.

Related infor- mation • Operating condition of service solenoid can be checked with monitoring function. (Code: 02301 Solenoid 2) • Method of reproducing failure code: Turn starting switch ON + Set machine in mode other than breaker mode (B). Possible causes and standard value in normal state Cause Defective service solenoid 1 (Internal disconnection) Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) 3 Defective pump controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

V06 (male) Resistance Between (1) – (2) 20 – 60 z a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (86) – R V06 (female) (1) t esis- Max. 1 z ance Wiring harness between V06 (female) (2) – R chassis ground (T09) t esis- Max. 1 z ance a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (86) – chassis ground 20 – 60 z