40 Troubleshooting UEN00242-00 Failure code [DWA2KB] Service Sol Short 1 Circuit diagram related to service solenoid PC210, 230, 240-8 43 User code Failure code Trouble Service solenoid short (Pump controller system) — DWA2KB Contents of trouble • When output to service solenoid is turned ON, short circuit was detected in circuit. Action of controller • Turns output to service solenoid OFF • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Hydraulic circuit for attachment is not does not change to single operation circuit.
Related infor- mation • Operating condition of service solenoid can be checked with monitoring function. (Code: 02301 Solenoid 2) • Method of reproducing failure code: Turn starting switch ON + Set machine in breaker mode (B). Possible causes and standard value in normal state Cause Defective service solenoid 1 (Internal short circuit or ground fault) Ground fault in wiring har- 2 ness (Short circuit with GND circuit) 3 Defective pump controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V06 (male) Resistance Between (1) – (2) 20 – 60 z Between (1) – chassis ground Min.
1 Mz a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (86) – R V06 (female) (1) t esis- Min. 1 Mz ance a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (86) – chassis ground 20 – 60 z