Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DWK0KA] 2-stage Relief Sol Discon

UEN00242-00 40 Troubleshooting Failure code [DWK0KA] 2-stage Relief Sol Discon 1 44 PC210, 230, 240-8 User code Failure code Trouble 2-stage relief solenoid disconnection (Pump controller system) — DWK0KA Contents of trouble • When output to 2-stage relief solenoid is turned OFF, disconnection was detected in circuit. Action of controller • None in particular. (Since no current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem that appears on machine • Power maximizing function does not work. • Travel power is low. Related infor- mation • Operating condition of 2-stage relief solenoid can be checked with monitoring function. (Code:

02300 Solenoid 1) • Method of reproducing failure code: Turn starting switch ON + Set machine in mode other than (L). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 2-stage relief sole- noid (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V02 (male) Resistance Between (1) – (2) 20 – 60 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C02 (female) (109) – V02 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – V02 (female) (2) Resis- tance Max. 1 z 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (109) – (115), (117), (120) 20 – 60 z