40 Troubleshooting UEN00244-00 E-12 Contents of display by machine monitor are different from applicable machine 1 E-13 Machine monitor does not display some items 1 E-14 Function switch does not work 1 PC210, 230, 240-8 31 Trouble Contents of display by machine monitor are different from applicable machine. Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective model code signal a Turn starting switch ON and carry out troubleshooting (with monitoring function). Monitoring code Normal display 00200 Controller model code PC210-8: PC210 PC240-8:
PC240 If display of monitoring is abnormal, carry out troubleshooting for failure code [DA29KQ]. 2 Defective machine monitor If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble • Machine monitor does not display some items. Related infor- mation • The LCD panel sometimes has black points (points which are not lighted) and bright points (points which do not go off) for the reason of its characteristics. If the number of the bright points and black points does not exceed 10, those points are not a failure or a defect.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor (LCD panel) a Turn starting switch ON and carry out troubleshooting. When following switches are operated, if all LCD panel is lighted up (all surface becomes white), LCD panel is normal. • Operation of switches: [4] + [F2] (Press simultaneously) 2 Defective machine monitor (body) If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble • Function switch does not work. Related infor- mation • Condition of signal of function switch can be checked with monitoring function.
(Code: 04503 Monitor function switch) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)