UEN00244-00 40 Troubleshooting E-15 Auto-decelerator does not operate normally 1 32 PC210, 230, 240-8 Trouble (1) When auto-decelerator switch is operated, auto-decelerator monitor does not light up or does not go off. Related infor- mation • Condition of signal of auto-decelerator switch can be checked with monitoring function. (Code: 04504 Monitor 1st, 2nd line switches) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) Trouble (2) Auto-decelerator is not operated or reset with lever.
Related infor- mation • Set speed of auto-decelerator is 1,400 rpm. If fuel control dial is not set above this speed, auto- decelerator is not operated or reset. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PPC pressure sig- nal a Start engine and carry out troubleshooting (with monitoring func- tion). Monitoring code Item Normal display 01900 Pressure switch 1 Swing When lever is operated: ON When lever is in neutral: OFF Travel Boom lower Boom raise Arm curl Arm dump 01901 Pressure switch 2 Bucket curl When lever is operated: ON When lever is in neutral:
OFF Bucket dump Service If display of monitoring is abnormal, carry out troubleshooting for E-26 Monitoring function does not display lever control signal nor- mally. 2 Defective machine monitor If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 3 Defective pump controller If cause 1 is not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 4 Defective engine controller If cause 1 is not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)