UEN00244-00 40 Troubleshooting E-17 Travel speed does not change 1 Circuit diagram related to travel speed shifting solenoid 34 PC210, 230, 240-8 Trouble (1) When travel speed switch is operated, travel speed monitor does not change. Related infor- mation • Condition of signal of travel speed switch can be checked with monitoring function. (Code: 04504 Monitor 1st, 2nd line switches) Possible cause and standard value in norma state s Cause l 1 Defective machine monitor Standard value in normal state/Remarks on troubleshooting Machine monitor may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.) Trouble (2) When travel speed is shifted, actual travel speed does not change. Related infor- mation • If cause 1 occurs, actual travel speed does not lower when travel speed is shifted to Lo. Possible cause and standard value in norma state Cause Hot short (Short circuit with s 1 24V circuit) in wiring harness l 2 Defective machine monitor 3 Defective pump controller Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between C02 (female) (87) – V04 (female) (1) Voltage Max.
1 V If cause 1 is not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) If cause 1 is not detected, pump controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)