UEN00244-00 40 Troubleshooting E-23 Air conditioner does not operate normally (including air conditioner abnormality record) 1 44 PC210, 230, 240-8 Trouble (1) When air conditioner switch is operated, air conditioner control screen is not displayed. Related infor- mation • Condition of air conditioner switch signal can be checked with monitoring function. (Code: 04505 Monitor 3rd, 4th line switches, 04506 Monitor 5th line switch) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective machine monitor Machine monitor may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.) Trouble (2) When air conditioner switch is operated, air conditioner does not operate at all. Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 11 If fuse is broken, circuit probably has ground fault. (See cause 4.) 2 Defective fuse in unit If fuse in unit is broken, circuit in unit probably has ground fault.
(See cause 4.) 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-11 – fuse in unit – ACW (wiring side) (6) Resis- tance Max. 1 z Wiring harness between ACW (wiring side) (16) – chassis ground (T07) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-11 – fuse in unit – ACW (wiring side) (6), – circuit branch end Resis- tance Min.
1 Mz 5 Defective air conditioner con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. ACW (wiring side) Voltage Between (6) – (16) 20 – 30 V If above voltage is normal, air conditioner controller may be defec- tive. 6 Defective machine monitor If causes 1 – 5 are not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)