40 Troubleshooting UEN00244-00 PC210, 230, 240-8 45 Trouble (3) Air does not come out (Air flow is insufficient). Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective blower relay (Inter- nal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON (coil side). R20 (male) Resistance Between (1) – (3) 140 – 340 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting (contact side).
R20 Air conditioner switch Voltage Between (4) – chassis ground Air blow position 20 – 30 V 2 Defective power transistor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Fan switch If air flow changes according to operation of fan switch, power transistor is normal. Operate between Low and Medium and High. 3 Defective blower motor (Internal defect) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. MB (wiring side) Air conditioner switch Voltage Between (1) – (2) Air blow position 20 – 30 V If above voltage is normal and blower motor does not revolve, blower motor is defective.
4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-11 – fuse in unit – R20 (female) (1) Resis- tance Max. 1 z Wiring harness between R20 (female) (3) – ACW (wiring side) (36) Resis- tance Max. 1 z Wiring harness between F01-11 – R20 (female) (5) Resis- tance Max. 1 z Wiring harness between R20 (female) (4) – MB (wiring side) (1) Resis- tance Max. 1 z Wiring harness between MB (wiring side) (2) – PTR (wiring side) (3) Resis- tance Max.
1 z Wiring harness between PTR (wiring side) (1) – chassis ground (T07) Resis- tance Max. 1 z Wiring harness between PTR (wiring side) (2) – ACW (wiring side) (8) Resis- tance Max. 1 z Wiring harness between PTR (wiring side) (4) – ACW (wiring side) (7) Resis- tance Max. 1 z