UEN00244-00 40 Troubleshooting 46 PC210, 230, 240-8 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 5 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between R20 (female) (3) – ACW (wiring side) (36) Resis- tance Min. 1 Mz Wiring harness between R20 (female) (4) – MB (wiring side) (1) Resis- tance Min. 1 Mz Wiring harness between MB (wiring side) (2) – PTR (wiring side) (3) Resis- tance Min. 1 Mz Wiring harness between PTR (wiring side) (2) – ACW (wiring side) (8) Resis- tance Min.
1 Mz 6 Defective air conditioner con- troller If causes 1 – 5 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 7 Defective air conditioner sys- tem If causes 1 – 5 are not detected, air conditioner system may be defective. See Machine Component Volume of Shop Manual, Air conditioner, Troubleshooting.