40 Troubleshooting UEN00244-00 PC210, 230, 240-8 47 Trouble (4) Air is not cooled (Cooling performance is insufficient). Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective compressor relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON (coil side). R21 (male) Resistance Between (1) – (3) 140 – 340 z a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting (contact side).
R21 Air conditioner switch Voltage Between (2) – chassis ground Cooling position 20 – 30 V 2 Defective internal air sensor Internal air sensor may be defective. Carry out troubleshooting for Abnormality in internal air sensor. 3 Defective high and low pres- sure switches High and low pressure switches may be defective. Carry out trou- bleshooting for “Abnormality in refrigerant”. 4 Defective compressor clutch (Internal defect) Compressor clutch may be defective. Check it directly. 5 Defective compressor (Inter- nal defect) Compressor may be defective. Check it directly.
6 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-11 – fuse in unit – R21 (female) (1) Resis- tance Max. 1 z Wiring harness between R21 (female) (3) – ACW (wiring side) (35) Resis- tance Max. 1 z Wiring harness between F01-11 – R21 (female) (4) Resis- tance Max. 1 z Wiring harness between R21 (female) (2) – AC02 (female) (1) Resis- tance Max. 1 z 7 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between R21 (female) (3) – ACW (wiring side) (35) Resis- tance Min. 1 Mz Wiring harness between R21 (female) (2) – AC02 (female) (1) Resis- tance Min. 1 Mz 8 Defective air conditioner con- troller If causes 1 – 7 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 9 Defective air conditioner sys- tem If causes 1 – 7 are not detected, air conditioner system may be defective. See Machine Component Volume of Shop Manual, Air conditioner, Troubleshooting.