Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — E-23 Air conditioner does not operate normally (including air conditioner abnormality record)

UEN00244-00 40 Troubleshooting 48 PC210, 230, 240-8 Trouble (5) Air conditioner abnormality record: Communication condition “CAN disconnection”, Communication condition “Abnormal” Related infor- mation • While abnormality in communication is being detected, “CAN disconnection” is displayed. • If abnormality in communication has been detected and reset, “Abnormality” is displayed. • If “CAN disconnection” is displayed as communication condition, communication cannot be carried out normally. Accordingly, condition of other items is not displayed. • Method of reproducing abnormality record: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between N10 (female) (2) – CM02 (female) (8), (9) Resis- tance Max. 1 z Wiring harness between N10 (female) (1) – CM02 (female) (10) Resis- tance Max. 1 z 2 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between N10 (male) (2) – CM02 (female) (8), (9), – C01 (female) (45), – CE02 (female) (46), – K02 (female) (A), – N08 (male) (3) Resis- tance Min. 1 Mz Wiring harness between N10 (female) (1) – CM02 (female) (10), – C01 (female) (64), – CE02 (female) (47), – K02 (female) (B), – N08 (male) (10) Resis- tance Min. 1 Mz 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. N10 (male) (2) – CM02 (female) (8), (9), – C01 (female) (45), – CE02 (female) (46), – K02 (female) (A), – N08 (male) (3) Voltage Max.

5.5 V Wiring harness between N10 (female) (1) – CM02 (female) (10), – C01 (female) (64), – CE02 (female) (47), – K02 (female) (B), – N08 (male) (10) Voltage Max. 5.5 V 4 Defective CAN terminal resistance (Internal short cir- cuit or disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. K02 (male) Resistance Between (A) – (B) 47 – 67 z 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.) 6 Defective machine monitor If causes 1 – 4 are not detected, machine monitor may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.)