Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — H-10 Work equipment does not move singly

UEN00245-00 40 Troubleshooting H-9 Speed or power of bucket is low 1 H-10 Work equipment does not move singly 1 14 PC210, 230, 240-8 Trouble • Speed or power of bucket is low. Related information • Carry out all troubleshooting in power mode (P) of working mode. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of right PPC valve (bucket circuit) a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting.

Right work equipment control lever PPC valve output pressure Neutral 0 MPa {0 kg/cm2} Bucket curl Bucket dump 2.84 – 3.43MPa {29 – 35 kg/cm2} 2 Malfunction of bucket control valve (spool) Spool of bucket control valve may have malfunction. Check it directly. 3 Malfunction of bucket control valve (pressure compensa- tion valve) Pressure compensation valve of bucket control valve may have malfunction. Check it directly. 4 Malfunction or defective seal of bucket control valve (safety-suction valve) Safety-suction valve of bucket control valve may have malfunction or defective seal. Check it directly.

5 Malfunction of service con- trol valve (LS shuttle valve) LS shuttle valve of service control valve may have malfunction. Check it directly. 6 Defective bucket cylinder a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Right work equipment control lever Leakage from bucket cylinder Bucket curl relief 20 cc/min Trouble (1) Boom does not move singly. (2) Arm does not move singly. (3) Bucket does not move singly. Related information • Carry out all troubleshooting in power mode (P) of working mode.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of PPC valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Work equipment control lever PPC valve output pressure Neutral 0 MPa {0 kg/cm2} Operated 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of control valve (spool) Spool of control valve may have malfunction. Check it directly.