40 Troubleshooting UEN00245-00 H-21 Travel speed does not change or travel speed is low/high 1 *: Travel speed Lo can be adjusted with the adjusting function of the machine monitor. Accordingly, if the initial value has been changed, the measured value varies more or less. PC210, 230, 240-8 23 Trouble • Travel speed does not change or travel speed is low/high Related information • Carry out all troubleshooting in power mode (P) of working mode. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of LS-EPC valve a Run engine at high idle and carry out troubleshooting (with monitoring function).
Travel speed Travel lever Monitoring code: 01500 Lo Operated 663 mA (PC210-8) 578 mA (PC240-8) (* Reference) Mi 424 mA (PC210-8) 641 mA (PC240-8) Hi 0 mA a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Travel speed Travel lever LS-EPC valve output pressure Lo Neutral Approx. 2.9 MPa {Approx. 30 kg/cm2} Hi Operated 0 MPa {0 kg/cm2} 2 Malfunction of travel speed shifting solenoid valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Travel speed Travel lever Travel speed shifting solenoid valve output pressure Lo Neutral 0 MPa {0 kg/cm2} Hi Operated Approx. 2.9 MPa {Approx.
30 kg/cm2} 3 Malfunction of travel motor (speed shifting section) Speed shifting section of travel motor may have malfunction. Check it directly.