UEN00245-00 40 Troubleshooting H-22 Travel system does not move (only one side) 1 24 PC210, 230, 240-8 Trouble • Travel system does not move (only one side). Related information • Carry out all troubleshooting in power mode (P) of working mode. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective seal of travel con- trol valve (suction valve) Seal of suction valve of travel control valve may have malfunction. Check it directly. 2 Defective seal of travel motor (safety valve) Seal of safety valve of travel control valve may have malfunction. Check it directly.
a Motors of same type on forward and reverse sides or on right and left sides may be checked by replacing them with each other and seeing change of condition. 3 Defective seal of travel motor (check valve) Seal of check valve of travel control valve may have malfunction. Check it directly. a Motors of same type on forward and reverse sides or on right and left sides may be checked by replacing them with each other and seeing change of condition. 4 Malfunction of travel motor (parking brake) Parking brake of travel motor may have malfunction. Check it directly. 5 Defective travel motor a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting.
Travel lever Leakage from travel motor Travel system relief 27.2 l/min 6 Defective final drive Final drive may have internal defect. Check it directly. a It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.