Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — H-23 Upper structure does not swing

40 Troubleshooting UEN00245-00 H-23 Upper structure does not swing 1 PC210, 230, 240-8 25 Trouble (1) Upper structure does not swing in either direction. Related information • Carry out all troubleshooting in power mode (P) of working mode. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of swing holding brake solenoid valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting.

Left work equipment control lever Swing holding brake solenoid valve output pressure Neutral 0 MPa {0 kg/cm2} Left swing Right swing 2.9 MPa {30 kg/cm2} 2 Malfunction of swing control valve (spool) Spool of swing control valve may have malfunction. Check it directly. 3 Malfunction of swing motor (parking brake) Parking brake of swing motor may have malfunction. Check it directly. 4 Defective adjustment or malfunction of swing motor (safety valve) a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting.

Swing lock switch Left work equipment control lever Swing relief pressure ON Swing relief 28.9 – 32.9 MPa {295 – 335 kg/cm2} If oil pressure does not become normal after adjustment, swing motor safety valve may have malfunction or internal defect. Check safety valve directly. 5 Defective swing motor a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Swing lock switch Left work equipment control lever Leakage from swing motor ON Swing relief Max. 10 l/min 6 Defective swing machinery Swing machinery may have internal defect. Check it directly. a It may be checked by abnormal sound, abnormal heating, metal chips in drain oil, etc.