Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — H-30 Oil flow in attachment circuit cannot be controlled

40 Troubleshooting UEN00245-00 H-29 Attachment circuit is not changed 1 Attachment installation specification H-30 Oil flow in attachment circuit cannot be controlled 1 Attachment installation specification PC210, 230, 240-8 31 Trouble • Attachment circuit is not changed. Related information • When attachment installation specification is employed, service circuit is changed as follows according to selected working mode. 1) ATT mode: Service circuit is changed to double acting circuit and safety valve is set to low pressure. 2) B mode: Service circuit is changed to single acting circuit and safety valve is set to high pressure.

• Safety valve set pressure on only B port side is changed; that on A port side is kept low. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of ATT return selector solenoid valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Working mode ATT return selector solenoid valve output pressure ATT mode 0 MPa {0 kg/cm2} B mode 2.9 MPa {30 kg/cm2} 2 Malfunction of ATT return selector valve ATT return selector valve may have malfunction. Check it directly.

3 Malfunction of service control valve (safety valve) Safety valve (B port side) of service control valve may have malfunction. Check it directly. Trouble • Oil flow in attachment circuit cannot be controlled. Related information • When attachment installation specification is employed, oil flow in service circuit changes according to selected user mode. • Procedure for adjusting oil flow in ATT mode of working mode is different from that in B mode. For details, see Operation and Maintenance Manual.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of ATT flow adjustment EPC valve ATT flow adjustment EPC valve may have malfunction. Check it directly. 2 Malfunction of service PPC valve Service PPC valve may have malfunction. Check it directly.