Komatsu — 3.4.6 FAULT AND INFORMATION MESSAGE LIST

OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Fault No. 590: (593) $h: Shutdown: Hydraulic oil level too low Help: - Fill up hydraulic oil. - Check level sensor B4 and B50. Fault No. 596: (599) $h: Faulty monitor channel engine speed 2 Help: Frequency converter E8-2 for speed of engine 2 shows inadmissible values - Check frequency converter E8-2 and pick-up 3B64-2 Fault No. 602: (605) $h: Help: Fault No. 608: (611) $h: Help: Fault No. 614: (617) $h: Start of engine 1 blocked by high pressure filter #4 Help: Differential pressure switch B8-1 not closed. - Check cables to differential pressure switch B8-1. Fault No. 620: (623) $h:

Start of engine 2 blocked by high pressure filter #8 Help: Differential pressure switch B8-2 not closed. - Check cables to differential pressure switch B8-2. Fault No. 626: (629) $h: Start of engine 1 blocked by high pressure filter #2 Help: Differential pressure switch B6-1. - Check cables to differential pressure switch B6-1. Fault No. 632: (635) $h: Fire in the power house (Shutdown) Fire suppression system 9K1 actuated. - Inform the fire brigade. - Evacuate endangered Persons. - Fight the fire and recharge the system Help: 177