3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS OPERATION Fault No. 638: (641) $h: Start of engine 1 blocked by high pressure filter #3 Help: Differential pressure switch B7-1 not closed. - Check cables to differential pressure switch B7-1. Fault No. 644: (647) $h: Start of engine 2 blocked by high pressure filter #5 Help: Differential pressure switch B5-2 not closed. - Check cables to differential pressure switch B5-2. Fault No. 650: (653) $h: Start of engine 2 blocked by high pressure filter #6 Help: Differential pressure switch B6-2 not closed. - Check cables to differential pressure switch B6-2. Fault No. 656: (659) $h: Start of engine 2 blocked by high pressure filter #7 Help:
Differential pressure switch B7-2 not closed. - Check cables to differential pressure switch B7-2. Fault No. 662: (665) $h: High pressure filter #2 restricted. Stop the engine 1 Help: Differential pressure switch B6-1 not closed. - Clean or replace filter element. - Check pump Fault No. 668: (671) $h: High pressure filter #3 restricted. Stop the engine 1 Help: Differential pressure switch B7-1 not closed. - Clean or replace filter element. - Check pump Fault No. 674: (677) $h: High pressure filter #5 restricted. Stop the engine 2 Help: Differential pressure switch B5-2 not closed. - Clean or replace filter element. - Check pump 178