OPERATION 3.17 OPERATION OF THE LUBRICATION SYSTEM ADJUSTMENTS OF THE CENTRAL LUBRICATION SYSTEM Manual actuation Mode of the Lubrication System with Service Key The manual actuation in the Service mode is useful for testing the electrical and hydraulic functions of the of the lubrication system. The pause time is reduced to 30 seconds and the holding time to 15 seconds permitting rapid sequences of lubrication cycles. Both lubrication systems can be set to the manual actuation mode. In the manual actuation mode all monitoring functions of the system are made inoperative and, because of the very short pause and holding times, grease will not reach to all lubrica- tion points.
Carry out manual lubrication by using the service key 1. Insert key into service switch (3) and set to operating position. 2. Actuate the rotary switch (1) on the instrument panel. The message # SERVICE appears on the display. Up to ten repeated actuation of the switch are possible. The lubrication cycles are counted and displayed in the cycle counter win- dow. 3. After finishing the manual lubrication remove service key. The system returns to the normal timer settings. Adjustments of the Central Lubrication System The following adjustments can be made with the menu control of the ECS system: Level 4:
Service / Settings - 4 - Settings * CONDITION INDICATION * - 4 - Settings (minutes) * PAUSE TIME : * - 4 - Settings * LUBE CYCLE COUNTER : * Refer to section "ELECTRONIC MONITORING AND CONTROL SYSTEM ECS" for description of adjustment procedure. 275 CAUTION CAUTION