. MAINTENANCE MAINTENANCE PROCEDURE REPLACE HYDRAULIC TANK ADDITIONAL BREATHER ELEMENT WARNING and may cause burns. Wait for the top CHECK NITROGEN GAS CHARGE PRESSURE IN ACCUMULATOR (for breaker) 4 - 72 The immediately after the temperature to go d own before starting the w ork. When removing the oil f iller cap , turn it slowl y to release the internal pressure, then 1. nut breath assembl hydraulic tank, t hen remov e cover (3). 2. Replace filte r element (4) w ith a new e lement. 3. Install cover (3) and nut (2) at th of the (If equipped) A special t oo l is needed for inspecting and charging w ith nitrogen Have your Komatsu distributor inspect and charge th e accumulator.