Scania — Coolant pump

Engine Tier-3 710655- Ch 1 page 136 4. Prise off the seal using two screwdrivers and separator plates. Note: Do not damage the pump housing gasket surface. 5. Apply sealing agent (501350) to the inside and outside (brass sleeve) of the sealing ring. Make sure that no sealing agent gets onto other sealing surfaces. The seal ring is removed Important! Sealing agent (501350) should be used sparingly. There is a risk of the sliding surfaces being glued together. 501351 6. Press in the new sealing ring with drift 501351 until the edge of the brass sleeve abuts against the pump housing. Keep it under pressure for about 10 seconds. Note: It is very important that tool 501351 is used.

It is designed to correctly preload the spring which holds the seal. 7. Press on the impeller using drift 501351 until the clearance between the gasket surface of the pump housing and the end of the impeller shaft is 13.3 - 13.7 mm. The new seal ring is pressed in Important! The shaft must not change position in the pump housing as there is a danger that the sealing ring would then also change its position. Puller for pulley 501348 Drift for pulley 501349 Puller for impeller 501354 Drift for pressing in sealing ring and for impeller 501351 A = 13,3 - 13,7 mm The clearance is measured SHOP MANUAL MT26-31 - 06.2005