Scania — Ecom standard settings code

Engine Tier-3 710655- Ch 1 page 24 Ecom standard settings code From Main Menu, Select: S6 Program E2 parameters Read values Make changes Write values SHOP MANUAL MT26-31 - 06.2005 CID Description Limits Typical Value Unit MT Value FE17 Low idle, ref engine speed 0 - 3200 650 rpm 650 FE21 Low idle, ref engine speed controller.

0 - 1 1 0 = use basic low idle, adjustable with CC-buttons 1 = Use FE17, not adjustable with CC-buttons FE65 Oil temperature sensor on EMS available 0 - 1 0/1 0 = Not available 1 = Available FE63 Use safety switch on accelrator pedal 0 -1 1 1 0 = Not available 1 = Available FE67 Diesel fuel density, used only for fuel rate calculation 0 - 2000 840 g/litre 840 FD7D Reduced high idle after start 0 - 1 0 = Enable 1 = Disable FC8D Type of governor 0 - 1 1 1 0 = RQ 1 = RQV FCB1 High idle, ref engine speed 0 - 3200 23 - 2400 rpm 2420 FD6F Coolant level sensor 0 - 1 0/1 0 = Not present 1 = From coordinator FD6D Reaction to low coolant level 0, 1, 2, 6 0 = Alarm only 1 = Torque limitation 2 = Stop engine 6 = Stop engine with override option