Scania — Ecom standard settings code

Engine Tier-3 710655- Ch 1 page 25 SHOP MANUAL MT26-31 - 06.2005 CID Description Limits Typical Value Unit MT Value FCB7 Reaction due to low oil pressure 0, 1, 2, 6 0 = Alarm only 1 = Torque limitation 2 = Stop engine 6 = Stop engine with override option FCB6 Reaction due to high coolant temperature 0, 1, 2, 3, 0/1/6 0 = Alarm only 1 = Torque limitation on low limit 2 = Stop engine on high limit 3 = Torque limitation and stop engine 6 = Stop engine with override option 7 = Torque limitation and stop engine with override option FCAF Engine coolant temperature shut-off limit 0 - 150 105 °C 105 FCF3 Engine coolant temperature torque limitation limit 0 - 150 95 °C 102 FCB5 Reaction on CAN or accelrator pedal error 0, 1, 2, 3, 4, 8 0/1 0 = No action, low level 1 = Increased low idle 2 = CAN shut-off 3 = CAN shut-off and increased low idle 4 = AUX AN as redundant accelrator pedal _ 8 = Always use AUX AN accelrator pedal _ FC81 PTO mode 0, max engine speed 0 - 3200 3000 rpm 3000 FC82 PTO mode 1, max engine speed 0 - 3200 3000 rpm 3000 FC83 PTO mode 3, max engine speed 0 - 3200 3000 rpm 3000 FC80 PTO mode 3, fixed engine speed 0 - 3200 1500 rpm 1100 FD09 PTO mode 0, max torque 0 - 5100 5100 rpm 5100 FD0B PTO mode 1, max torque 0 - 5100 5100 rpm 5100 FD0D PTO mode 2, max torque 0 - 5100 5100 rpm 5100 FD0F PTO mode 3, max torque 0 - 5100 5100 rpm 5100