Engine Tier-3 710655- Ch 1 page 39 Renewing the control unit Tightening torques Control unit, screws 22 Nm Work description IMPORTANT! The control unit may suffer damage if it is powered when you unplug it. Before removing the control unit you must switch off the power with the starter key and wait for the EMS warning lamp to go out. 1 Remove the covers over the connectors on the control unit and then unplug the connectors. 2 Remove the control unit fixing screws and lift off the control unit. 3 Fit the new control unit and tighten the screws to 22 Nm. 4 Plug in the connectors on the control unit. 5 Do the necessary programming with ECOM. Start the engine.
Check the fault codes and then delete them in accordance with the routine in troubleshooting booklet or with the PC-tool ECOM if it is available. SHOP MANUAL MT26-31 - 06.2005