Doosan Infracore D18NAP — P0191 Rail Pressure Sensor fault (Sensor drift at key-on)

5. Failure Diagnosis P0191 Rail Pressure Sensor fault (Sensor drift at key-on) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the feedback rail pressure of rail pressure sensor is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the feedback rail pressure of rail pressure is within the threshold during restricted condition, fault code is cleared. 5. Inspection Items 5 - 50 Code Causes Impact P0191 Faulty IMV (sticking,leaking etc), Faulty rail pressure sensor. (Aged or malfunction) Faulty Injector LPC(Low pressure circuit)problem.

(leakage, fuel is not supplied due to some reason.) HPC(High pressure circuity)problem.(leakage etc) CE lamp Flashing Torque Reduction Lv1 Delay engine stop NO ECU Pin Description 1 138 VREF1 Rail Pressure Sensor 2 119 Rail Pressure Sensor Return 3 135 Rail Pressure Sensor Step Inspection Standard Value YES NO 1 P0191 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 This fault could be caused by pushing vehicle while engine is off. Vehicle been pushed? Clear fault. Poor detection Step 3 4 VEXT fault present? Step 5 Step 6 5 Problem with one of these sensors causing loss of Vext:

Disconnect sensors one by one checking if fault disappear to find which one is faulty. If None is found faulty, check short circuit and isolation of Vext lines on the harness 6 Check sensor connection Connection problem? Do necessary repair Step 7 7 Check ECU connection Connection problem? Do necessary repair Step 8 8 Check continuity and electrical insulation Electrical problem? Fix harness Step 10 9 Change sensor + rail Problem still present? Call Hot-line