Doosan Infracore D18NAP — P0002 Rail Pressure Control fault (RPC using IMV only)

5. Failure Diagnosis P0002 Rail Pressure Control fault (RPC using IMV only) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the resistance of IMV is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the resistance of IMV is within the threshold during restricted condition, fault code is cleared. 5.

Inspection Items 1) A 5 - 51 Code Causes Impact P0002 Faulty injector (sticking, coking, leaking etc), Injector wiring problem, Faulty IMV CE lamp Flashing Torque Reduction Lv1 NO ECU Pin Description 1 177 Inlet Metering Valve PWM 2 - Pbatt Step Inspection Standard Value YES NO 1 P0002 is raised on diagnostic tool? Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch. Step 3 3 Please do visual inspection throughout all fuel line & electric wire of injector. (Low pressure circuit & high pressure circuit) Is there any leakage or wire problem? If you cannot find with your eyes, You can check leakage during engine running in machine stationary condition.

Step 4 Step 5 4 Please fix the leakage. After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 10 minutes. Fault code is cleared? O.K Step 5 5 Please do the Shut off test & Run up test for detecting which injector has fault or not. Do you find faulty injector? Step 6 Call DOOSAN Hot line 6 Change the faulty injector as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Step 7 7 Change the high pressure pump with DOOSAN A.S support. Fault code is cleared? O.K Call DOOSAN Hot line