Doosan Infracore D18NAP — P0335 Crank signal over speed fault

5. Failure Diagnosis P0335 Crank signal over speed fault 1. Overview 2. Condition for Running Diagnostic Since cranking phase 3. Condition for Setting the Fault Code Crank sensor signal is out of range 4. Condition for Clearing the Fault Code Crank sensor signal is in a range 5. Inspection Items 5 - 76 Code Causes Impact P0335 Sensor connection problem Wiring fault. Fault with trigger wheel. Fault with crank signal processing in ECU. Faulty ECU live or ground. Fault with ECU wiring or connectors CE lamp ON Low idle RPM increase NO ECU Pin Description 1 136 Crank Sensor Neg 2 160 Crank Sensor Pos 3 - Not used Step Inspection Standard Value YES NO 1 P0335 is occurred on diagnostic tool?

Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check sensor connection Connection problem? Do necessary repair Step 4 4 Check ECU connection Connection problem? Do necessary repair Step 5 5 Check continuity and electrical insulation Electrical problem? Fix harness Step 6 6 If scope available, display CAM and Crank signals on the scope Signals not conform to template? Change Hall effect or VR sensor Step 7 7 New sensor connected Problem still present? Change APS target wheel Step 8 8 New target wheel fitted Problem still present? Call Hot-line Problem solved