Doosan Infracore D18NAP — P0344 CAM signal fault (missing event within the expected window)

5. Failure Diagnosis P0344 CAM signal fault (missing event within the expected window) 1. Overview 2. Condition for Running Diagnostic Since cranking phase 3. Condition for Setting the Fault Code Cam sensor signal is missed 4. Condition for Clearing the Fault Code Cam sensor signal is coming normally. 5. Inspection Items 5 - 77 Code Causes Impact P0344 Sensor connection problem wiring fault Fault with cam trigger wheel Fault with cam wheel signal processing in ECU Faulty ECU live or ground Fault with ECU wiring or connectors Engine fault causing camshaft speed variation.

CE lamp ON Torque Reduction Lv0 Low idle RPM increase NO ECU Pin Description 1 - Pbatt 2 159 CAM Shaft Position Sensor 3 147 CAM Shaft Position Sensor Return Step Inspection Standard Value YES NO 1 P0344 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check sensor connection Connection problem? Do necessary repair Step 4 4 Visually check sensor Sensor problem? Change sensor Step 5 5 Check ECU connection Connection problem? Do necessary repair Step 6 6 If scope available, display CAM and Crank signals on the scope Signals not conform to template?