Doosan Infracore D18NAP — P0341 Cam signal drift higher than threshold

5. Failure Diagnosis P0341 Cam signal drift higher than threshold 1. Overview 2. Condition for Running Diagnostic Since cranking phase 3. Condition for Setting the Fault Code Cam sensor signal is out of range 4. Condition for Clearing the Fault Code Cam sensor signal is in a range 5.

Inspection Items 5 - 79 Code Causes Impact P0341 Sensor connection problem wiring fault Fault with cam trigger wheel Fault with cam wheel signal processing in ECU Faulty ECU live or ground Fault with ECU wiring or connectors Engine fault causing camshaft speed variation Low idle RPM increase NO ECU Pin Description 1 - Pbatt 2 159 CAM Shaft Position Sensor 3 147 CAM Shaft Position Sensor Return Step Inspection Standard Value YES NO 1 P0341 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check sensor connection Connection problem? Do necessary repair Step 4 4 Visually check sensor Sensor problem?

Change sensor Step 5 5 Check ECU connection Connection problem? Do necessary repair Step 6 6 If scope available, display CAM and Crank signals on the scope Signals not conform to template? Do necessary repair Step 7 7 Check continuity and electrical insulation Electrical problem? Fix harness Step 8 8 Check Cam target wheel Target wheel problem? Change target wheel Step 9 9 Check distribution Distribution problem? Fix distribution Call Hot-line