Doosan Infracore D18NAP — P0340 Cam signal last learnt value is outside of limits

5. Failure Diagnosis P0340 Cam signal last learnt value is outside of limits 1. Overview 2. Condition for Running Diagnostic Since cranking phase 3. Condition for Setting the Fault Code Cam sensor learning is failed 4. Condition for Clearing the Fault Code Cam sensor learning is succeed 5.

Inspection Items 5 - 80 Code Causes Impact P0340 Sensor connection problem wiring fault Fault with cam trigger wheel Fault with cam wheel signal processing in ECU Faulty ECU live or ground Fault with ECU wiring or connectors Engine fault causing camshaft speed variation Low idle RPM increase NO ECU Pin Description 1 - Pbatt 2 159 CAM Shaft Position Sensor 3 147 CAM Shaft Position Sensor Return Step Inspection Standard Value YES NO 1 P0340 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check sensor connection Connection problem? Do necessary repair Step 4 4 Visually check sensor Sensor problem?

Change sensor Step 5 5 Check ECU connection Connection problem? Do necessary repair Step 6 6 If scope available, display CAM and Crank signals on the scope Signals not conform to template? Do necessary repair Step 7 7 Check continuity and electrical insulation Electrical problem? Fix harness Step 8 8 Check Cam target wheel Target wheel problem? Change target wheel Step 9 9 Check distribution Distribution problem? Fix distribution Call Hot-line